Abstract
In the laboratory, we often receive phone calls from our clinical colleagues with questions about decisions we have made that might affect their patient’s care. For example, enquiries about why we have rejected a sample or why we were unable to provide a particular result due to a pre-analytical or technical error. In this series of short articles, we want to try and address some of the most common questions we get asked, with the aim of educating the wider workforce in a way that is simple to understand, about the decisions we make in the laboratory. We hope that with a greater understanding, the number of avoidable errors might be reduced.
In this article, we explore the pre-analytical challenges associated with short volume sodium citrate anti-coagulated blood samples and why these must be rejected.
References
International Organization for Standardization. Single-use containers for human venous blood specimen collection. ISO, 2017. Available at: https://www.iso.org/obp/ui/#iso:std:iso:6710:ed-2:v1:en (accessed 2.3.19).
Lippi G, Salvagno GL, Montagnana M, Lima-Oliveira G, Guidi GC, Favaloro EJ. Quality standards for sample collection in coagulation testing. Seminars in Thrombosis and Hemostasis 2012;38(6):565-575. Available from: https://doi.org/10.1055/s-0032-1315961
Favaloro EJ, Lippi G, Adcock DM. Preanalytical and postanalytical variables: the leading causes of diagnostic error in hemostasis? Seminars in Thrombosis and Hemostasis 2008;34(7):612-634. Available from: https://doi.org/10.1055/s-0028-1104540
Pa W. Clinical and Laboratory Standard Institute C. Methods for dilution antimicrobial susceptibility tests for bacteria that grow aerobically. Approved standard M7-A7. Clinical and Laboratory Standard Institute. 2006.
Mikaelsson M.E. (1991) The role of calcium in coagulation and anticoagulation. In: Sibinga C.T.S., Das P.C., Mannucci P.M. (eds) Coagulation and Blood Transfusion. Developments in Hematology and Immunology, vol 26. Boston, MA: Springer;1991.
Sabbatani L. Calcium et citrate trisodique dans la coagulation du sang, de la lymphe et du lait. Arch Ital Biol 1901;36:397-415.
Pekelharing CA. Ueber die Gerinnung des Blutes. 1. DMW-Deutsche Medizinische Wochenschrift 1892;18(50):1133-6.
Peterson P, Gottfried EL. The effects of inaccurate blood sample volume on prothrombin time (PT) and activated partial thromboplastin time (aPTT). Thrombosis and Haemostasis 1982;47(02):101-3.
BD. General BD Vacutainer® blood collection tubes FAQ. Available at: https://www.bd.com/en-us/offerings/capabilities/specimen-collection/blood-specimen-collection/venous-collection/bdvacutainer-blood-collection-tubes/vacutainer-bloodcollection-tube-faq/general-tubes-faq (accessed 3.3.19).
Reneke J, Etzell J, Leslie S, Ng V, Gottfried E. Prolonged prothrombin time and activated partial thromboplastin time due to underfilled specimen tubes with 109 mmol/L (3.2%) citrate anticoagulant. American Journal of Clinical Pathology. 1998;109(6):754-757. Available from: https://doi.org/10.1093/ajcp/109.6.754